Connecting the Battery Cable
We ship the 30.00 COMMERCIAL DR RAPID-FEED
CHIPPER with the negative terminal battery cable
disconnected. This prevents the battery from discharging
during shipment. Before using your 30.00 COMMERCIAL
DR RAPID-FEED CHIPPER, you must connect the battery
cable.
Battery
Terminal
Hardware
Battery
Positive
Battery
Cable
Negative
Battery
Cable
Tools and Supplies Needed:
Two 5/16" Wrenches
1. Remove the hardware from the negative terminal of
the Battery with two 5/16" wrenches (Figure 10).
Figure 10
2. Position the negative Battery Cable and secure with
the negative terminal hardware using two 5/16"
wrenches.
Adding Engine Oil and Gasoline
YOU MUST ADD OIL BEFORE STARTING THE ENGINE. THIS MACHINE IS SHIPPED WITHOUT
OIL. TRACES OF OIL MAY BE IN THE RESERVOIR FROM FACTORY TESTING, BUT
YOU MUST ADD
OIL BEFORE STARTING THE ENGINE. FILL THE RESERVOIR SLOWLY CHECKING THE DIPSTICK
FREQUENTLY TO AVOID OVERFILLING.
TO GET AN ACCURATE READING WHEN CHECKING THE OIL LEVEL:
- THE MACHINE SHOULD BE ON A LEVEL SURFACE.
- THE DIPSTICK
SHOULD BE PUSHED ALL THE WAY IN TO ENSURE AN ACCURATE OIL LEVEL
READING.
Capacities
Engine SAE 30 Oil - 56 oz. (1.66 L)
Fuel Tank Unleaded gasoline, 9 US quarts (8.5 L)
Tip: To avoid confusion, we recommend leaving the caps on the gas and oil fills until you are ready to
pour either gasoline or oil into the correct fill.
NOTE: Use SAE 30 high detergent oil classified “For Service SF, SG, SH, SJ” or higher. Do not use special
additives. Other types of oil could cause problems operating your machine. Please refer to your
Engine Owner’s Manual for detailed oil information.
CONTACT US AT www.DRpower.com or CALL TOLL FREE 1-800-DR-OWNER 17